Sign In | Join Free | My benadorassociates.com |
|
Brand Name : UNI-Cables
Model Number : RVFV-K
Certification : ISO9001
Place of Origin : CHINA
MOQ : 1000M
Price : Negotiable
Supply Ability : 70000 Meters per Week
Delivery Time : 15-18 working days
Packaging Details : 1000 Meters in a Wooden Reel
Voltage Rating (Uo/U) : 600/1000V
Maximum Operating Temperature : +90°C
Core Identification : Blue Brown Green/Yellow
Conductor : Class 1 solid or Class 2 stranded copper conductor
Insulation : XLPE
Inner Sheath : PVC (Polyvinyl Chloride)
Armour : Two steel tapes
Outer Sheath : PVC (Polyvinyl Chloride)
Type RVFV VVFV and RVFV-K VVFV-K Double Steel Tape or Aluminum Tape Armored
APPLICATION
These cables are especially suitable for fixed installations that may be subject to mechanical aggression. They are highly recommended for use in installations in warehouses, production plants and agricultural facilities where the presence of rodents could imply a threat to cable integrity. At the same time, its use is recommended for street lighting installations. In some cases, these cables are used in those places where there is a potential explosion hazard such as petrol stations or flammable product warehouses.
CABLE STANDARDS
UNE 21123-2, IEC 60502, EN 60332-1, IEC 60332-1
Cable Construction
- Rigid electrolytic annealed copper conductor
- Class 1 (up to 4 mm2 ) or 2 (from 6 mm2 upwards) in accordance with IEC 60228
- Class 5 for (RVFV-K/VVFV-K) in accordance with IEC 60228
- XLPE insulation (RVFV/RVFV-K) or PVC insulation (VVFV/ VVFV-K) according to IEC 60502
- up to 5 conductors: by colors (RVFV/RVFV-K)
- 6 or more conductors: black numbered + green/yellow. (VVFV/VVFV-K)
- Extruded continuous PVC bedding type ST1/ST2 of standard IEC 60502.
- Double steel or aluminum tape armour
- Flexible PVC compound outer sheath type ST1/ST2 of standard IEC 60502
Technical Characteristics:
- Working voltage: 600/1000 volts
- Test voltage: 2000 volts
- Minimum bending radius: 10 x Ø
- Working temperature: -15º C to +90º C
- Short circuit temperature: +250º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km
DIMENSIONS
AWG | No. of Cores x Nominal Cross Sectional Area # x mm² |
Nominal Overall Diameter mm |
Nominal Weight kg/km | AWG | No. of Cores x Nominal Cross Sectional Area # x mm² |
Nominal mm |
Nominal Weight kg/km |
6 | 1×16 | 14.4 | 345 | 3/0 | 3×95/50 | 41.3 | 4613 |
4 | 1×25 | 16 | 477 | 4/0 | 3×120/70 | 46.9 | 6,023 |
2 | 1×35 | 17.3 | 582 | 300MCM | 3×150/70 | 54.7 | 7455 |
1 | 1×50 | 18.5 | 722 | 350MCM | 3×185/95 | 55.1 | 8890 |
2/0 | 1×70 | 20.7 | 962 | 500MCM | 3×240/120 | 62.5 | 11055 |
3/0 | 1×95 | 22.1 | 1173 | 16 | 4×1.5 | 13.2 | 275 |
4/0 | 1×120 | 24.6 | 1522 | 14 | 4×2.5 | 14.4 | 339 |
300MCM | 1×150 | 26.5 | 1821 | 12 | 4×4 | 15.1 | 419 |
350MCM | 1×185 | 28.5 | 2230 | 10 | 4×6 | 17.3 | 545 |
500MCM | 1×240 | 31.7 | 235 | 8 | 4×10 | 19.8 | 770 |
16 | 2×1.5 | 12.3 | 227 | 6 | 4×16 | 22.3 | 1062 |
14 | 2×2.5 | 12.8 | 259 | 4 | 4×25 | 26.5 | 1602 |
12 | 2×4 | 13.6 | 311 | 16 | 5×1.5 | 14.4 | 320 |
10 | 2×6 | 15.8 | 411 | 14 | 5×2.5 | 15.3 | 390 |
8 | 2×10 | 17.8 | 552 | 12 | 5×4 | 17.2 | 509 |
6 | 2×16 | 19.6 | 726 | 10 | 5×6 | 18.8 | 640 |
16 | 3×1.5 | 12.8 | 252 | 8 | 5×10 | 21.3 | 909 |
14 | 3×2.5 | 13.3 | 293 | 6 | 5×16 | 25.2 | 1304 |
12 | 3×4 | 14.5 | 367 | 16 | 6×1.5 | 15.8 | 394 |
10 | 3×6 | 16.3 | 468 | 16 | 7×1.5 | 15.8 | 412 |
8 | 3×10 | 18.3 | 641 | 16 | 10×1.5 | 17.8 | 521 |
6 | 3×16 | 20.4 | 870 | 16 | 12×1.5 | 19.2 | 603 |
6 | 3×16/10 | 21.5 | 996 | 16 | 16×1.5 | 20.8 | 714 |
4 | 3×25/16 | 25.1 | 1468 | 16 | 19×1.5 | 21.8 | 792 |
2 | 3×35/16 | 27.9 | 1854 | 16 | 24×1.5 | 23.3 | 914 |
1 | 3×50/25 | 29.6 | 2101 | 16 | 27×1.5 | 25.4 | 1015 |
Class 1 25mm 3core Armoured Power Cable PVC RVFV Double Steel Aluminum Images |